the influence of energy targets and economic concerns in design strategies for a residential nearly-zero energy building

Clicks: 225
ID: 241767
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #17 of 33 articles by views in zhong yao cai = zhongyaocai = journal of chinese medicinal materials

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Finding cost-optimal solutions towards nearly-zero energy buildings in accordance with the Energy Performance of Buildings Directive (EPBD) is a challenging task. In order to reach the 20-20-20 targets, EU energy policy has introduced new ambitious levels for the large-scale spread of nearly-zero energy buildings (nZEBs) and the concept of the cost-optimal level, defined as the energy performance level, which leads to the lowest cost during the estimated economic lifecycle of the building. Consequently, building design has begun a challenge involving both energy targets and economic concerns. The aim of this research is to analyze an example building of a new single family house, using the cost-optimal methodology, in order to define how energy and economic aspects influence the preliminary design phase of the project and, in particular, the choice of the performance features of some components of the project itself, such as envelope elements and systems. The impact on energy performances of different configurations for the building envelope and heating, ventilation and air conditioning (HVAC) systems was assessed with the dynamic simulation software EnergyPlus. Finally, the costs of the different design scenarios were estimated, according to the European Standard EN 15459:2007 to establish which of them had the lowest global cost and, consequently, represents the cost-optimal level for the design configurations analyzed. In order to test the stability of the results obtained, different sensitivity analyses were carried out.
Reference Key
barthelmes2014buildingsthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Verena Marie Barthelmes;Cristina Becchio;Marta Carla Bottero;Stefano Paolo Corgnati
Journal zhong yao cai = zhongyaocai = journal of chinese medicinal materials
Year 2014
DOI
10.3390/buildings4040937
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.