hemostatic effect of aluminum chloride in liver bleeding: an animal model study
Clicks: 9
ID: 241265
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
2.4
/100
9 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #176 of 179 articles by views in asian journal of chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 179 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background: Controlling parenchymal hemorrhage especially in liver parenchyma, despite all the progress in surgical science, is still one of the challenges surgeons face saving patients’ lives and there is a research challenge among researchers in this field to introduce a more effective method. This study attempts to determine the haemostatic effect of aluminum chloride and compare it with that of the standard method (simple suturing technique) in controlling bleeding from liver parenchymal tissue.
Methods: This is an experimental study. In this animal model study 60 male Wistar rats were randomly allocated into six groups and each of which contains 10 mouse. An incision, two centimeters (cm) long and half a cm deep, was made on each rat’s liver and the hemostasis time was measured once using aluminum chloride with different concentrations (5%, 10%, 15%, 25%, and 50%) and then using the control method (i.e. controlling bleeding by simple suturing). The liver tissue was examined for pathological changes. Finally, the obtained data were entered into SPSS software and analyzed using Kruskal- wallis test, Mann- Whitney, Kolmogorov- Smirnov test.
Results: The mean time to hemostasis in groups of aluminum chloride concentration of 50%, 25%, 15%, 10% and 5% were respectively, 8.90, 13.10, 23.30, 30.30 and 37.8 seconds, also in the control group (suture) mean time of hemostasis was 60/81 seconds. The haemostatic times of different concentrations of aluminum chloride were significantly less than that of the control group (P< 0.001). There was a statistically significant difference between every two haemostatic times (P< 0.001). The pathologic examination showed the highest frequency of low grade inflammation based on the defined pathological grading.
Conclusion: Aluminum chloride compare to the control method (i.e. controlling liver bleeding by simple suturing) needs less time to control liver bleeding. Aluminum chloride is an effective agent in controlling liver hemorrhage in an animal model.
| Reference Key |
2014tehranhemostatic
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Saeed Nouri ;Mohammad Reza Sharif |
| Journal | asian journal of chemistry |
| Year | 2014 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.