dynamic distance direct ophthalmoscopy, a novel technique to assess accommodation in children

Clicks: 396
ID: 240063
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #34 of 456 articles by views in Bioinformatics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 456 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aim: To describe and compare dynamic distance direct ophthalmoscopy (DDDO) with dynamic retinoscopy (DR) in assessment of accommodation in children. Materials and Methods: This prospective observational study had four components. Component 1: to understand the characteristic digital images of DDDO. Component 2: to compare DDDO with DR for detection of accommodative defects in children (1-16 years). Component 3: to compare DDDO with DR for the detection of completeness of pharmacologically induced cycloplegia in children (5-16 years) and Component 4: to assess which one of the two techniques was more sensitive to detect onset of cycloplegia after instillation of 1% cyclopentolate eye drops. Results: Component 1: image analysis of DDDO on two subjects (7 years and 35 years) demonstrated superior pupillary crescent that progressively disappeared with increasing accommodation. Concurrently an inferior crescent appeared that became bigger in size with increasing accommodation. Component 2: the prevalence of defects in accommodation was 3.3% (33/1000 children). Three had unilateral accommodation failure. Sensitivity of DDDO was 94%, specificity 100%, positive predictive value 100%, negative predictive value 99%, and clinical agreement (kappa) 0.97. Component 3: in the detection of completeness of pharmacologically induced cycloplegia (n=30), the sensitivity of DDDO was 94%, specificity 96%, positive predictive value 97%, negative predictive value 93% and kappa 0.9. DR had two false positives. DDDO had one false negative. Component 4: DDDO detected onset of pharmacologically induced cycloplegia 5 min earlier than DR (n=5). Conclusion: DDDO is a novel, simple, clinical and reliable method to assess accommodation in young children. This test can assess the accommodative response of both eyes simultaneously.
Reference Key
kothari2012indiandynamic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Mihir Kothari;Suvarna Balankhe;Shalaka Paralkar;Deepali Nar;Shreya Bhagat;Shashank Ranade
Journal Bioinformatics
Year 2012
DOI
10.4103/0301-4738.94051
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.