fracture resistance of teeth restored with cast post and core: an in vitro study
Clicks: 174
ID: 239231
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
174 views
37 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #39 of 53 articles by views in sexuality and culture
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Context: Influence of luting agent, design of tooth preparation for cast posts on tooth resistance to fracture. Aim: To evaluate fracture resistance of teeth restored with cast posts and cores with or without cervical ferrule and cemented with zinc phosphate, glass ionomer, or resin cement. Materials and Methods: Sixty single-rooted maxillary first premolars of similar sizes were selected. Biomechanical preparation and post space preparation for cast post was done for all samples and then they were divided into two groups (n=30). Cervical ferrule preparation was done for Group A, and Group B was prepared without any cervical ferrule. Both groups were further divided into three subgroups (1, 2, and 3; n=10) Cast posts for subgroups 1, 2, and 3 were cemented with zinc phosphate, glass ionomer, and resin cement, respectively. A shearing load was applied to indented buccal cusp of specimens at an angle of 45° in universal testing machine at a cross-head speed of 1 mm/min until fracture. Results: Specimens with ferrule (Group A) had significantly higher shear bond strength values (mean 1503.37 N) than specimens without ferrule (Group B) (mean 1052.09 N). Conclusion: Inclusion of ferrule in tooth preparations for posts increased the fracture resistance regardless of the luting agent.
| Reference Key |
mankar2012journalfracture
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;S Mankar;N S Mohan Kumar;J V Karunakaran;S Senthil Kumar |
| Journal | sexuality and culture |
| Year | 2012 |
| DOI |
10.4103/0975-7406.100200
|