improving inland water quality monitoring through remote sensing techniques
Clicks: 266
ID: 238495
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
266 views
61 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #29 of 94 articles by views in población y desarrollo
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Chlorophyll-a (chl-a) levels in lake water could indicate the presence of cyanobacteria, which can be a concern for public health due to their potential to produce toxins. Monitoring of chl-a has been an important practice in aquatic systems, especially in those used for human services, as they imply an increased risk of exposure. Remote sensing technology is being increasingly used to monitor water quality, although its application in cases of small urban lakes is limited by the spatial resolution of the sensors. Lake Thonotosassa, FL, USA, a 3.45-km2 suburban lake with several uses for the local population, is being monitored monthly by traditional methods. We developed an empirical bio-optical algorithm for the Moderate Resolution Imaging Spectroradiometer (MODIS) daily surface reflectance product to monitor daily chl-a. We applied the same algorithm to four different periods of the year using 11 years of water quality data. Normalized root mean squared errors were lower during the first (0.27) and second (0.34) trimester and increased during the third (0.54) and fourth (1.85) trimesters of the year. Overall results showed that Earth-observing technologies and, particularly, MODIS products can also be applied to improve environmental health management through water quality monitoring of small lakes.
| Reference Key |
ogashawara2014isprsimproving
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Igor Ogashawara;Max J. Moreno-Madriñán |
| Journal | población y desarrollo |
| Year | 2014 |
| DOI |
10.3390/ijgi3041234
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.