evaluation of the reliability of measurements in cephalograms generated from cone beam computed tomography
Clicks: 163
ID: 238453
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
163 views
39 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #28 of 47 articles by views in biosaintifika: journal of biology & biology education
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
OBJECTIVE: The purpose was to compare angular and linear measurements generated in digital cephalometric radiographs and cephalograms synthesized from three-dimensional images. METHODS: Twenty-six individuals (12 men and 14 women) with mean age of 26.3 years were selected. Digital cephalometric radiographs and CBCTs were taken on the same day. The images were imported and analyzed on Dolphin Imaging V.10.5 software, which synthesized cephalograms in perspective projection and magnification of 9.7%. A single observer marked the points and repeated the procedure with an interval of time of ten days to evaluate intraexaminer error. In the statistical analysis paired Student's t test was used to establish the correlation between the measurements. RESULTS: The angular measurements GoGn.SN and IMPA, which involved the Gonial point (Go) and the linear measurements that involved the lips presented significant difference (p < 0.05). The other measurements presented good correlation. CONCLUSION: The measurements in the synthesized cephalograms proved to be reliable.
| Reference Key |
silva2013dentalevaluation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Maurício Barbosa Guerra da Silva;Bruno Cabús Gois;Eduardo Franzotti Sant'Anna |
| Journal | biosaintifika: journal of biology & biology education |
| Year | 2013 |
| DOI |
10.1590/S2176-94512013000400009
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.