evaluation of the mixtures ammonium phosphate/magnesium nitrate and palladium nitrate/magnesium nitrate as modifiers for simultaneous determination of cd, cr, ni and pb in mineral water by gfaas
Clicks: 139
ID: 237935
2004
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
139 views
28 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #31 of 43 articles by views in british journal of dermatology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A method is described for the simultaneous determination of Cd, Cr, Ni and Pb in mineral water samples by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer (THGA) and a longitudinal Zeeman-effect background correction system. The electrothermal behavior of analytes during pyrolysis and atomization steps was studied without modifier, in presence of 5 mug Pd and 3 mug Mg(NO3)2 and in presence of 50 mug NH4H2PO4 and 3 mug Mg(NO3)2. A volume of 20 muL of a 0.028 mol L-1 HNO3 solution containing 50 mug L-1 Ni and Pb, 10 mug L-1 Cr and 5 mug L-1 Cd was dispensed into the graphite tube at 20 °C. The mixture palladium/magnesium was selected as the optimum modifier. The pyrolysis and atomization temperatures were fixed at 1000 °C and 2300 °C, respectively. The characteristic masses were calculated as 2.2 pg Cd, 10 pg Cr, 42 pg Ni and 66 pg Pb and the lifetime of the graphite tube was around 600 firings. Limits of detection based on integrated absorbance were 0.02 mug L-1 Cd, 0.94 mug L-1 Cr, 0.45 mug L-1 Ni and 0.75 mug L-1 Pb, which exceeded the requirements of Brazilian Food Regulation that establish the maximum permissible level for Cd, Cr, Ni and Pb at 3 mug L-1, 50 mug L-1, 20 mug L-1 and 10 mug L-1, respectively. The recoveries of Cd, Cr, Ni and Pb added to mineral water samples varied within the 93-108%, 96-104%, 87-101% and 98-108% ranges, respectively. Results of analysis of standard reference materials (National Institute of Standards and Technology: 1640-Trace Elements in Natural Water; 1643d-Trace Elements in Water) were in agreement with certified values at the 95% confidence level.
| Reference Key |
r2004journalevaluation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Amorim Filho Volnei R;Fernandes Kelly G;Moraes Mercedes de;Gomes Neto José Anchieta |
| Journal | british journal of dermatology |