composite palladium-cobalt oxide films modified n-silicon electrode for photo-electrochemical detection of hydrogen peroxide

Clicks: 211
ID: 237413
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #69 of 435 articles by views in acta botânica brasílica

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 435 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A novel nonenzymatic hydrogen peroxide (H2O2) sensor was fabricated, based on composite Pd-Co oxide films modified n-silicon electrode. The modified electrode was consisted of platinum coated n-silicon as substrate prepared by vacuum evaporating a platinum coating and composite Pd-Co oxide films deposited by electrochemical technique. The morphology of the modified electrode was characterized via scanning electron microscope (SEM). The analytical performances of the modified electrode for determination of H2O2 were investigated by cyclic voltammetry (CV) and chronoamperometry. A new two electrodes photo-electrochemical cell has been used as sensor for H2O2 determination by photocurrent measurements at zero voltage. The sensor showed good photocurrent responses by adding different concentrations of H2O2 with a good stability. The linear ranges for the detection of H2O2 are 2 to 48 μM with a detection limit of 0.57 μM in pH=7.0 phosphate buffer solution (PBS). In addition, the sensor also exhibited superior stability, anti-interference and portability. These features demonstrated that the new photo-electrochemical sensor was suitable for detection of H2O2 on site outdoors.
Reference Key
yijun2016mateccomposite Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Zhang Yijun;Hu Jinchao;Wu Qiong;Li Huaixiang
Journal acta botânica brasílica
Year 2016
DOI
10.1051/matecconf/20166706078
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.