determination of repaglinide in human plasma by high-performance liquid chromatography–tandem mass spectrometry
Клики: 291
ID: 235851
2011
Метрики качества и эффективности статьи
Общее качество
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Вовлечённость читателей
Popular Article
30.0
/100
291 просмотры
36 читатели
Оценка качества ИИ
Не проанализировано
Readership in this journal
PopularRanked #24 of 88 articles by views in energy policy
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Аннотация
A rapid and sensitive method based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) has been developed for the determination of repaglinide in human plasma. The analyte and internal standard (I.S.), diazepam, were extracted from plasma (25 μL) by liquid–liquid extraction with diethyl ether–dichloromethane (60:40, v/v) and separated on a XDB-C18 column using acetonitrile–ammonium acetate buffer (pH 6.8, 0.01 mol/L) as mobile phase. The retention times of repaglinide and I.S. were 1.95 and 2.35 min, respectively. Detection was carried out using API 4000 mass spectrometer with an ESI interface operating in the multiple reaction monitoring (MRM) mode. The assay was linear over the concentration range 0.050–50 ng/mL with a limit of detection (LOD) of 0.010 ng/mL. Intra- and inter-day precisions (as relative standard deviation, R.S.D.) were ≤5.07% and ≤11.2%, respectively, and accuracy (as relative error, R.E.) was from −0.593% to −1.26%. The assay was successfully applied to a pharmacokinetic study involving a single oral administration of a tablet containing 2 mg repaglinide to each of 10 healthy volunteers.
| Ссылочный ключ |
zhang2011actadetermination
Используйте этот ключ для автоцитирования в рукописи при использовании
SciMatic Manuscript Manager или Thesis Manager
|
|---|---|
| Авторы | ;Jie Zhang;Feng Gao;Xin Guan;Yan-tong Sun;Jing-kai Gu;J. Paul Fawcett |
| Журнал | energy policy |
| Год | 2011 |
| DOI |
10.1016/j.apsb.2011.04.004
|
| URL | |
| Ключевые слова |
Цитирования
Цитирования не найдены. Чтобы добавить цитирование, свяжитесь с администратором по адресу info@scimatic.org
Комментарии
Комментариев пока нет. Будьте первым, кто прокомментирует эту статью.