hemoptise e hemotórax como apresentação de ruptura de aorta torácica hemoptysis and hemothorax as presentation of thoracic aortic rupture

Clicks: 276
ID: 235384
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #23 of 103 articles by views in 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Dissecção da aorta torácica é doença de grande mortalidade em sua fase inicial, mas pode, em alguns casos, se cronificar. Relatamos caso de paciente com dissecção crônica de aorta tipo B (Stanford), admitido na Emergência com confusão mental, dispnéia e relato de hemoptise importante. O eletrocardiograma mostrava alterações inespecíficas e a radiografia de tórax revelou opacificação do hemitórax esquerdo. O ecocardiograma transtorácico não evidenciou dissecção aórtica, mas demonstrou imagem compatível com hemotórax, ocasionando a suspeita de ruptura da aorta. O paciente evoluiu em colapso cardiovascular e óbito. Este caso descreve duas apresentações atípicas da dissecção de aorta: hemotórax e hemoptise importante.
Thoracic aortic dissection is a disease of great mortality in its initial phase, but in some cases it can assume chronic course. We report a case of a patient with Stanford type A1 aortic dissection, admitted with mental confusion, dyspnea and event of severe hemoptysis. Electrocardiogram showed unspecific change and chest X-ray revealed opacification of the left hemithorax. Transthoracic echocardiogram did not show aortic dissection, but showed image similar to hemithorax leading to the suspicion of aortic rupture. The patient developed cardiovascular collapse and evolved to death. This case describes two unusual presentations of aortic dissection: hemothorax and severe hemoptysis.
Reference Key
lima2009brazilianhemoptise Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Márcio Silva Miguel Lima;Marcelo Luiz Campos Vieira
Journal 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings
Year 2009
DOI
10.1590/S0102-76382009000200024
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.