flame atomic absorption spectrometric determination of trace amounts of silver after solid-phase extraction with 2-mercaptobenzothiazole immobilized on microcrystalline naphthalene

Clicks: 176
ID: 233680
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #94 of 215 articles by views in british journal of psychology (london, england : 1953)

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 215 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A simple and sensitive solid-phase extraction (SPE) procedure combined with flame atomic absorption spectrometry (FAAS) was designed for the extraction and determination of trace amounts of silver. A column of immobilized 2-mercaptobenzothiazole (MBT) on microcrystalline naphthalene was used as the sorbent. Silver was quantitatively retained on the column in the pH range of 0.5–6.0. After extraction, the solid mass consisting of silver complex and naphthalene was dissolved out of the column with 5.0 mL of dimethylformamide, and the analyte was determined by flame atomic absorption spectrometry (FAAS). Under the optimum experimental conditions, the adsorption capacity was found to be 1.18 mg of silver per gram of the sorbent. A sample volume of 800 mL resulted in a preconcentration factor of 160. The relative standard deviation obtained for ten replicate determinations at a concentration of 0.8 µg L−1 was 1.4%, and the limit of detection was 0.02 µg L−1. The method was successfully applied to the determination of silver in radiology film, waste water, and natural water samples. The accuracy was examined by recovery experiments, independent analysis by electrothermal atomic absorption spectrometry, and analysis of two certified reference materials.
Reference Key
shakerian2013journalflame Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Farid Shakerian;Ali Mohammad Haji Shabani;Shayessteh Dadfarnia;Mahdieh Shabani
Journal british journal of psychology (london, england : 1953)
Year 2013
DOI
10.1155/2013/465825
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.