suitability of different mapping algorithms for genome-wide polymorphism scans with pool-seq data

Clicks: 203
ID: 232969
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #130 of 194 articles by views in separation and purification technology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The cost-effectiveness of sequencing pools of individuals (Pool-Seq) provides the basis for the popularity and widespread use of this method for many research questions, ranging from unraveling the genetic basis of complex traits, to the clonal evolution of cancer cells. Because the accuracy of Pool-Seq could be affected by many potential sources of error, several studies have determined, for example, the influence of sequencing technology, the library preparation protocol, and mapping parameters. Nevertheless, the impact of the mapping tools has not yet been evaluated. Using simulated and real Pool-Seq data, we demonstrate a substantial impact of the mapping tools, leading to characteristic false positives in genome-wide scans. The problem of false positives was particularly pronounced when data with different read lengths and insert sizes were compared. Out of 14 evaluated algorithms novoalign, bwa mem and clc4 are most suitable for mapping Pool-Seq data. Nevertheless, no single algorithm is sufficient for avoiding all false positives. We show that the intersection of the results of two mapping algorithms provides a simple, yet effective, strategy to eliminate false positives. We propose that the implementation of a consistent Pool-Seq bioinformatics pipeline, building on the recommendations of this study, can substantially increase the reliability of Pool-Seq results, in particular when libraries generated with different protocols are being compared.
Reference Key
kofler2016g3:suitability Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Robert Kofler;Anna Maria Langmüller;Pierre Nouhaud;Kathrin Anna Otte;Christian Schlötterer
Journal separation and purification technology
Year 2016
DOI
10.1534/g3.116.034488
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.