the influence of platinum dopant on the characteristics of sno2thin film for gas sensor application
Clicks: 320
ID: 231610
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
320 views
39 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #8 of 23 articles by views in j am med assoc
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Doping of platinum on tin dioxide (SnO2) thin film for gas sensor application has been carried out using ion implantation techniques. The SnO2 thin film has been deposited using dc sputtering method at the conditions; operating pressure 5x10-2 torr, anode-cathode voltage 2.0 kV, substrate temperature 2000C and deposition time one hour. While the Pt ion implantation process were carried out at energy 60 keV and ion doses were varied. From scanning electron microscope (SEM) observation, it was found that SnO2:Pt thin film which was deposited by those parameters has a fine morphology with the grain size of thin film was in order of 0.7 – 1.0 μm and thickness 4.16 μm. From crystal structure analysis using XRD it was observed that the crystal planes of SnO2:Pt were (110), (101), (200), (211), (300), and (112) . From energy dispersive X-rays analysis (EDX) coupled with SEM, it was found that the chemical composition of SnO2:Pt thin film were 66.12%-at O, 1.23 %-at Si, 0.12 %-at Pt and 32.53 %-at Sn. It was also found that the influence of platinum dopant on SnO2 thin film can reduce significantly the resistance of thin film and from response time and sensitivities measurement showed that for every dose variation for different tested gas has a different respons time and sensitivities (no a specific pattern)
| Reference Key |
sujitno2006atomthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;T. Sujitno;Sudjatmoko |
| Journal | j am med assoc |
| Year | 2006 |
| DOI |
http://dx.doi.org/10.17146/aij.2006.118
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.