valores de referência para o teste cardiopulmonar para homens e mulheres sedentários e ativos valores de referencia para el test cardiopulmonar para hombres y mujeres sedentarios y activos reference values for cardiopulmonary exercise testing for sedentary and active men and women
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #64 of 230 articles by views in revista cubana de ciencias informáticas
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 230 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
FUNDAMENTO: Los valores de referencia de test cardiopulmonar (TCP) disponibles en el Brasil fueron derivados de ciclóergómetro, en población sedentaria y relativamente pequeña. OBJETIVO: Proveer valores de referencia para el TCP en brasileños de ambos sexos, sedentarios y activos. MÉTODOS: Entre 2006 y 2008, 3.992 TCP de individuos sanos fueron seleccionados de nuestro laboratorio. Atletas, fumantes, portadores de cualquier patología conocida, usuarios de medicación continua y obesos fueron excluidos. VO2 pico fue considerado VO2 máx. Analizamos también VO2 de umbral anaeróbico, ventilación máxima y pulso de oxígeno de acuerdo con sexo, franja etárea, sedentarios y activos. Las franjas etáreas fueron así divididas: G1 (15-24 años), G2 (25-34), G3 (35-44), G4 (45-54), G5 (55-64) y G6 (65-74). RESULTADOS: De acuerdo con las franjas etáreas, los valores medios de VO2 en ml/kg/min con los respectivos desviación-estándar fueron: Hombre activo: G1-50,6 ± 7,3; G2-47,4 ± 7,4; G3-45,4 ± 6,8; G4-40,5 ± 6,5; G5-35,3 ± 6,2; G6-30,0 ± 6,1. Mujer activa: G1-38,9 ± 5,7; G2-38,1 ± 6,6; G3-34,9 ± 5,9; G4-31,1 ± 5,4; G5-28,6 ± 6,1; G6-25,1 ± 4,4. Hombre sedentario: G1-47,4 ± 7,9; G2-41,9 ± 7,2; G3-39,0 ± 6,8; G4-35,6 ± 7,7; G5-30,0 ± 6,3; G6-23,1 ± 6,3. Mujer sedentaria: G1-35,6 ± 5,7; G2-34,0 ± 4,8; G3-30,0 ± 5,4; G4-27,2 ± 5,0; G5-23,9 ± 4,2; G6-21,2 ± 3,4. CONCLUSIÓN: Este artículo provee valores de referencia de VO2 máx, entre otros parámetros, en el Test Cardiopulmonar realizados en la cinta ergométrica en individuos de ambos sexos, activos y sedentarios.
BACKGROUND: The reference values for cardiopulmonary exercise testing (CPET) available in Brazil were derived from a cycle ergometer in a sedentary and relatively small population. OBJECTIVE: Provide reference values for CPET in Brazilians of both sexes, either sedentary or active. METHODS: From 2006 to 2008, 3,992 CEPT of healthy individuals were selected from our laboratory. Athletes, smokers, patients with any known pathology, users of continuous medication and obese patients were excluded. Peak VO2 was considered max VO2. We also analyzed the anaerobic threshold VO2, maximum ventilation and oxygen pulse according to sex, age, sedentary and active patients. Age groups were divided as follows: G1 (15-24), G2 (25-34), G3 (35-44), G4 (45-54), G5 (55-64) and G6 (65-74). RESULTS: According to age groups, the mean values of VO2 in ml/kg/min with their standard deviations were: Active man: G1-50.6 ± 7.3, G2-47, 4 ± 7.4, G3-45, 4 ± 6.8, G4-40.5 ± 6.5; G5-35.3 ± 6.2; G6-30.0 ± 6.1. Active woman: G1-38.9 ± 5.7; G2-38.1 ± 6.6; G3-34.9 ± 5.9; G4-31.1 ± 5.4; G5-28.6 ± 6.1; G6-25.1 ± 4.4. Sedentary man: G1-47.4 ± 7.9; G2-41.9 ± 7.2; G3-39.0 ± 6.8; G4-35.6 ± 7.7; G5-30.0 ± 6.3; G6-23.1 ± 6.3. Sedentary woman: G1-35.6 ± 5.7; G2-34.0 ± 4.8; G3-30.0 ± 5.4; G4-27.2 ± 5.0; G5-23.9 ± 4.2; G6-21.2 ± 3.4. CONCLUSION: This article provides reference values of max VO2, among other parameters, in the Cardiopulmonary Exercise Testing performed on the treadmill in individuals of both sexes, either active and sedentary.
| Reference Key |
herdy2011arquivosvalores
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Artur Haddad Herdy;Dorian Uhlendorf |
| Journal | revista cubana de ciencias informáticas |
| Year | 2011 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.