Catheter Dwell Time and Risk of Catheter Failure in Adult Patients with Peripheral Venous Catheters.

Clicks: 248
ID: 22694
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #37 of 55 articles by views in Journal of clinical nursing

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To explore whether the risk of peripheral venous catheters failure remained constant throughout catheter use in adult patients.Peripheral venous catheters, widely used in adult patients, may have a critical threshold dwell time associated with increased risk of catheter failure.Prospective, observational study. We have complied with the STROBE Checklist of items.This study was conducted from July to October 2018 in Hunan, China. Data on patient factors, catheter factors, and catheter failure events were collected. Poisson regression was used to assess the effect of catheter dwell time on catheter failure while adjusting for other variables.A total of 1477 patients were included in the analysis. There were 854 cases (57.8%) of catheter failure. The median dwell time to catheter failure was 52 h (interquartile range: 36-73 h). The incidence rate of catheter failure significantly increased by 1.1%/h in the first 38 h after catheter insertion. From 39-149 h, the incidence rate significantly decreased, and at >149 h, there was no significant change in the incidence rate. Meanwhile, factors like vascular quality and infused drugs showed having an impact on catheter failure events.The risk of catheter failure may not remain constant throughout the dwell time. The results suggest that nurses should assess the insertion site frequently in the first 38 h.The significant increase in the risk of catheter failure per hour may warrant close and frequent inspection of insertion site during the first 38 hours.
Reference Key
wei2019catheterjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wei, Tao;Li, Xu-Ying;Yue, Zhi-Ping;Chen, Yong-Yi;Wang, Yi-Ren;Yuan, Zhong;Lin, Qin;Tan, Yan;Peng, Si-Yi;Li, Xing-Feng;
Journal Journal of clinical nursing
Year 2019
DOI
10.1111/jocn.15035
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.