interrater reproducibility of knee movement analyses during the stance phase: use of anatomical landmark calibration with a rigid marker set

Clicks: 166
ID: 226073
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #36 of 50 articles by views in Asia-Pacific journal of oncology nursing

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objective. Measurements of knee joint movement in gait analysis may result in large errors caused by misplacement of reflective markers by the testers. To properly understand the measurement results, it is important to guarantee the reliability of the measurement method used for the purpose. The aim of this study was to confirm the interrater reproducibility of a measurement method with a rigid marker set (RMS). Methods. The study subjects were four healthy adults, and the testers were three physical therapists. The interrater reproducibility of the measurements was verified by using the coefficient of multiple correlations (CMCs) and the standard error of measurement (SEM). Results. The average CMCs values of 4 subjects in knee joint movement at the stance phase were greater than 0.8, and the average SEM values of 4 subjects in knee joint movement at the stance phase were also relatively good (maximum error: 2.42°). Conclusion. Based on these results, the measurement method with estimation of anatomical landmarks using the RMS can prevent misplacement during attachment of the reflective markers, as long as the testers have sufficient experience in attaching reflective markers.
Reference Key
fukaya2013rehabilitationinterrater Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager