left ventricular synchrony assessment: a comparative analysis using real time three-dimensional echocardiography and tissue doppler imaging

Clicks: 388
ID: 226070
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #11 of 78 articles by views in New England Journal of Medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objective: Left ventricular regional synchrony can be analyzed bythree-dimensional echocardiography (3D Echo) as well as by tissueDoppler imaging (TDI). The aim of the study was to compare leftventricular synchrony assessment by both methods. Methods: Aprospective study of 59 patients (36 males, mean age of 50 years ±11 years), 39 with normal cardiac anatomy and eletrocardiography(group 1), and 20 with dilated cardiomyopathy and wide QRS (group 2).Patients underwent 3D echocardiographic – quantification of ejectionfraction (LVEF), volumes and percentage dyssynchrony index (DI)of left ventricular 6, 12 and 16 segments. By TDI we measured leftventricular QS electromechanical interval in the basal segment of themitral valve annulus of the septum, lateral, anterior and inferior walls,as well as tissue dyssynchrony index (%). The statistical analysis wasperformed using Pearson’s correlation coefficient, 95% CI, p < 0.05,linear regression equation and Bland and Altman test. Results: In thenormal group, the correlation coefficient (r) for TDI DI and 3D 6 DIwas 0.5142, p = 0.001; for 3D 12 DI, r = 0.4110, p = 0.009, and for3D 16 DI, r = 0.3761, p = 0.018. In the dilated group, the correlationcoefficient (r) for TDI DI and 3D 6 DI was 0.3920, p = 0.047; for 3D 12DI, r = 0.1344, p = 0.572; and for 3D 16 DI, r = 0.1105, p = 0.643.Conclusion: In both groups, a poor correlation was observed in leftventricular synchrony assessment by 3D Echo and Tissue Doppler.
Reference Key
vieira2007einsteinleft Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Marcelo Luiz Campos Vieira;Alexandre Ferreira Cury;Gláucia Maria Penha Tavares;Edgar Bezerra Lira Filho;Adriana Cordovil;Ana Clara Tude Rodrigues;Cláudia Gianini Mônaco;Gustavo Naccarato;Cláudio Henrique Fischer;Samira Saady Morhy
Journal New England Journal of Medicine
Year 2007
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.