use of a unique long pre-curved sheath to facilitate femoral placement of coronary sinus catheters

Clicks: 233
ID: 225876
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #19 of 63 articles by views in Medical decision making : an international journal of the Society for Medical Decision Making

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Methods: Catheterization of the coronary sinus (CS) from the femoral vein is widely used during electrophysiologic procedures. Access to the CS may be difficult. To address this problem we explored the utility of a long pre-formed (SAFL™) sheath in a cohort of consecutive patients requiring CS cannulation in the electrophysiology laboratory. This unique sheath has distal curvatures in 2 planes, potentially facilitating CS cannulation.Results: 68 patients were studied with an average age of 63±16 years. In twelve patients (18%), standard femoral CS cannulation was ineffective. In six of these patients, the SAFL™ sheath allowed for cannulation, and in six the subclavian approach was required. There were no significant differences in age, left ventricular ejection fraction, or echocardiographically estimated pulmonary artery systolic pressure between the various subgroups. There was a trend towards a larger left atrial size in the atrial flutter group (46mm±7.9) versus all others (40.6mm±6.3, P=.076). Left atrial size was 37 mm in the femoral sheath-requiring group versus 44 mm in all others (P=NS).Conclusion: Utilization of a unique commercially available long preformed sheath helps to provide femoral CS catheter access in selected cases in the electrophysiology laboratory.
Reference Key
shandling2009indianuse Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Adrian H. Shandling;Daniel Rieders;Melanie Edwards
Journal Medical decision making : an international journal of the Society for Medical Decision Making
Year 2009
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.