examination and testing of crane beams of an overflow dam
Clicks: 150
ID: 225699
2012
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
30.0
/100
149 views
10 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
The following conclusions were made upon completion of the testing of crane beams:
The lowest rigidity is demonstrated by welded beams exposed to temporary mobile loads; the maximal buckling caused by temporary mobile loads is equal to 12 mm, or 1/1,1790 of the span; the rigidity of crane beams of an overflow dam meets the requirements set by Section E2.1 of Construction Rules 20.13330.2011 "Loads and Actions".
In general, the authors state that the crane beams of the span structure of the overflow dam are in a serviceable operating condition, according to their opinion issued upon completion of examination and testing procedures. The recommendation is to regularly tighten screw nuts and to install high-strength bolts in the points of missing rivets. The authors also recommend applying a rust-proofing coating to all metal structures of the dam spans.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (134 words).
Try re-searching for a better abstract.
| Reference Key |
serafimovich2012vestnikexamination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Kholopov Igor' Serafimovich;Zubkov Vladimir Aleksandrovich;Khurtin Vladimir Anatol'evich |
| Journal | PsyCh journal |
| Year | 2012 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org