Development of a cuffless blood pressure measurement system.

Clicks: 137
ID: 22365
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #122 of 127 articles by views in conference proceedings : annual international conference of the ieee engineering in medicine and biology society ieee engineering in medicine and biology society annual conference

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 127 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study constructs a novel blood pressure measurement device without the air cuff to overcome the problem of discomfort and portability. The proposed device measures the blood pressure through a mechanism that is made of silicon rubber and pressure transducer. The system uses a microcontroller to control the measurement procedure and to perform the necessary computation. To verify the feasibility of the constructed device, ten young volunteers were recruited. Ten blood pressure readings were obtained using the new system and were compared with ten blood pressure readings from bedside monitor (Spacelabs Medical, model 90367). The results indicated that, when all the readings were included, the mean pressure, systolic pressure and diastolic pressure from the new system were all higher than those from bedside monitor. The correlation coefficients between these two were 0.15, 0.18 and 0.29, for mean, systolic and diastolic pressures, respectively. After excluding irregular apparatus utilization, the correlation coefficient increased to 0.71, 0.60 and 0.41 for diastolic pressure, mean pressure and systolic pressure, respectively. We can conclude from these results that the accuracy can be improved effectively by defining the user regulation more precisely. The above mentioned irregular apparatus utilization factors can be identified and eliminated by the microprocessor to provide a reliable blood pressure measurement in practical applications in the future.
Reference Key
shyu2012developmentconference Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Shyu, Liang-Yu;Kao, Yao-Lin;Tsai, Wen-Ya;Hu, Weichih;
Journal conference proceedings : annual international conference of the ieee engineering in medicine and biology society ieee engineering in medicine and biology society annual conference
Year 2012
DOI
10.1109/EMBC.2012.6346359
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.