An automated Y-maze based on a reduced instruction set computer (RISC) microcontroller for the assessment of continuous spontaneous alternation in rats.
Clicks: 234
ID: 22354
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
81.1
/100
234 views
187 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #16 of 47 articles by views in Behavior research methods
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Continuous spontaneous alternation behavior (SAB) in a Y-maze is used for evaluating working memory in rodents. Here, the design of an automated Y-maze equipped with three infrared optocouplers per arm, and commanded by a reduced instruction set computer (RISC) microcontroller is described. The software was devised for recording only true entries and exits to the arms. Experimental settings are programmed via a keyboard with three buttons and a display. The sequence of arm entries and the time spent in each arm and the neutral zone (NZ) are saved as a text file in a non-volatile memory for later transfer to a USB flash memory. Data files are analyzed with a program developed under LabVIEW® environment, and the results are exported to an Excel® spreadsheet file. Variables measured are: latency to exit the starting arm, sequence and number of arm entries, number of alternations, alternation percentage, and cumulative times spent in each arm and NZ. The automated Y-maze accurately detected the SAB decrease produced in rats by the muscarinic antagonist trihexyphenidyl, and its reversal by caffeine, having 100 % concordance with the alternation percentages calculated by two trained observers who independently watched videos of the same experiments. Although the values of time spent in the arms and NZ measured by the automated system had small discrepancies with those calculated by the observers, Bland-Altman analysis showed 95 % concordance in three pairs of comparisons, while in one it was 90 %, indicating that this system is a reliable and inexpensive alternative for the study of continuous SAB in rodents.
| Reference Key |
heredialpez2016anbehavior
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Heredia-López, Francisco J;Álvarez-Cervera, Fernando J;Collí-Alfaro, José G;Bata-García, José L;Arankowsky-Sandoval, Gloria;Góngora-Alfaro, José L; |
| Journal | Behavior research methods |
| Year | 2016 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org