measurement systems to detect the time-dependant development of concrete spalling under fire exposure

Clicks: 5
ID: 223535
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #407 of 435 articles by views in acta botânica brasílica

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 435 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In order to analyse the behaviour of concrete under fire exposure experimental investigations are used [1]. This practice is expensive and very time-consuming. So, it is essential to get as most suitable information out of such experiments as possible. At the present, most standard experiments are only capable of comparing a condition of concrete before and after the experiments [1]. Unfortunately, information of the time-dependent development of the damaging process cannot be resolved. In order to fully understand the mechanism of dynamic concrete damage under fire exposure, this information is crucial. Therefore, it is necessary to develop measurement systems which are able to monitor and detect the entire exposure process and its consequences. These systems should be applied additionally to the temperature monitoring, the visual inspection and a weighting of the specimen before and after the experiments. For this purpose volume-oriented non-destructive testing methods are considered. It is possible to use ultrasonic systems or impact-echo methods, but the most suitable are acoustic emission techniques. With this method it is possible to monitor damage processes of the complete specimen volume and during the whole time of the experiments. The paper will present results of experimental investigations where such systems have been successfully applied to test the feasibility, practicability and the usefulness of different measurement systems to verify the time-dependant development of concrete spalling under fire exposure.
Reference Key
r.2013matecmeasurement Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Richter R.;Dehn F.;Schmidt J.;Juknat M.;Grosse C.U.
Journal acta botânica brasílica
Year 2013
DOI
10.1051/matecconf/20130603006
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.