influence of the ion treatment regime on defects density and surface destruction of the polycrystalline glass

Clicks: 132
ID: 223328
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #420 of 442 articles by views in BMJ open

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 442 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract

The ion beam technology is used for finish treatment of large-scale optic parts to achieve highest precision and minimal surface roughness. The surface roughness increases during the ion treatment of polycrystalline materials in contrast to usual optic materials. This is caused, first, by polycrystalline structure of material and, second, by micro-defects appearing on its surface. The aim of the work is to investigate the influence of ion processing conditions on the amount of defects formed on the polycrystalline glass CO-115M.

As an ion source, was used the anode layer accelerator with electromagnetically focusing ion beam and with excess charge compensation on the residual gas. The ion accelerator provided Gaussian ion current distribution on the treated sample surface. The accelerator had three operation conditions: 1 – Ud = 2 kV, Id = 110 mA; 2 – Ud = 3 kV, Id = 110 mA; 3 – Ud = 3,8 kV, Id = 50 mA (Ud – discharge voltage, Id – discharge current). Processing time was 30 min.

For quantitative estimation of surface destruction degree the surface defects density was used which is equal to the ratio of total area of defects within the region under consideration to entire area. Defects area was calculated using the microphotography of treated surface.

The investigations have shown that the defects occurred as microscopic chips in all operation conditions of treatment. The defects density distribution corresponds to ion current distribution on the sample surface. With increasing ion current power density a size of defects has grown and their amount has increased. With the constant power density an increasing acceleration voltage results in decreasing density of defects. It was shown that a process of appearing defects is of the threshold nature. For each accelerated voltage there is a power density at which defects do not appear. The work results may be useful to choose the ion beam processing operation conditions in manufacturing large-scale optics.

Reference Key
duhopel'nikov2014naukainfluence Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;D. V. Duhopel'nikov;S. G. Ivakhnenko;E. V. Vorob'ev;A. A. Azerbaev
Journal BMJ open
Year 2014
DOI
10.7463/1214.0748236
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org