minimization of sample pretreatment for al, cu and fe determination in coconut water by electrothermal atomic absorption spectrometry
Clicks: 264
ID: 222095
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
264 views
43 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #10 of 43 articles by views in british journal of dermatology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Fast and reliable methods for the direct determination of Al, Cu and Fe in unprocessed coconut water by electrothermal atomic absorption spectrometry are proposed. For Fe determination, 100 µL of sample were diluted with 1400 µL of 0.1% v/v HNO3. Aliquots of 10 µL of this solution were injected into the graphite tube without any chemical modifier. For Al and Cu determinations, samples were slightly diluted (1250 µL of sample + 250 µL of 0.6% v/v HNO3 + 0.6% m/v Triton X-100) directly into the auto sampler cups. In this case, aliquots of 10 µL of an oxidant mixture (15% v/v H2O2 + 1.0% v/v HNO3) were co-injected with 15 µL of samples or analytical solutions into the graphite tube. The oxidant mixture minimized the carbonaceous residues formation and increased graphite tube lifetime in 75%, allowing up to 200 heating cycles. The detection limits and characteristic masses were 1.0 mg L-1 and 30 pg for Al, 0.7 µg L-1 and 20 pg for Cu, and 2.0 µg L-1 and 10 pg for Fe, respectively. The reliability of the proposed methods was evaluated by addition and recovery tests (104 ? 1% for Al, 98 ? 3% for Cu, and 97 ? 1% for Fe).
| Reference Key |
juliana2006journalminimization
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Naozuka Juliana;Oliveira Pedro V. |
| Journal | british journal of dermatology |
| Year | 2006 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.