impedance control for robotic rehabilitation: a robust markovian approach
Clicks: 186
ID: 219938
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
186 views
25 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #20 of 22 articles by views in industrial \& engineering chemistry research
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The human-robot interaction has played an important role in rehabilitation robotics and impedance control has been used in the regulation of interaction forces between the robot actuator and human limbs. Series elastic actuators (SEAs) have been an efficient solution in the design of this kind of robotic application. Standard implementations of impedance control with SEAs require an internal force control loop for guaranteeing the desired impedance output. However, nonlinearities and uncertainties hamper such a guarantee of an accurate force level in this human-robot interaction. This paper addresses the dependence of the impedance control performance on the force control and proposes a control approach that improves the force control robustness. A unified model of the human-robot system that considers the ankle impedance by a second-order dynamics subject to uncertainties in the stiffness, damping, and inertia parameters has been developed. Fixed, resistive, and passive operation modes of the robotics system were defined, where transition probabilities among the modes were modeled through a Markov chain. A robust regulator for Markovian jump linear systems was used in the design of the force control. Experimental results show the approach improves the impedance control performance. For comparison purposes, a standard H∞ force controller based on the fixed operation mode has also been designed. The Markovian control approach outperformed the H∞ control when all operation modes were taken into account.
| Reference Key |
jutinico2017frontiersimpedance
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Andres L. Jutinico;Andres L. Jutinico;Jonathan C. Jaimes;Felix M. Escalante;Juan C. Perez-Ibarra;Marco H. Terra;Adriano A. G. Siqueira |
| Journal | industrial \& engineering chemistry research |
| Year | 2017 |
| DOI |
10.3389/fnbot.2017.00043
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.