application of synchrotron through-the-substrate microdiffraction to crystals in polished thin sections

Clicks: 194
ID: 217756
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #27 of 40 articles by views in european journal of orthopaedic surgery & traumatology : orthopedie traumatologie

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The synchrotron through-the-substrate X-ray microdiffraction technique (tts-μXRD) is extended to the structural study of microvolumes of crystals embedded in polished thin sections of compact materials [Rius, Labrador, Crespi, Frontera, Vallcorba & Melgarejo (2011). J.Synchrotron Rad. 18, 891–898]. The resulting tts-μXRD procedure includes some basic steps: (i) collection of a limited number of consecutive two-dimensional patterns (frames) for each randomly oriented crystal microvolume; (ii) refinement of the metric from the one-dimensional diffraction pattern which results from circularly averaging the sum of collected frames; (iii) determination of the reciprocal lattice orientation of each randomly oriented crystal microvolume which allows assigning the hkl indices to the spots and, consequently, merging the intensities of the different frames into a single-crystal data set (frame merging); and (iv) merging of the individual crystal data sets (multicrystal merging) to produce an extended data set suitable for structure refinement/solution. Its viability for crystal structure solution by Patterson function direct methods (δ recycling) and for accurate single-crystal least-squares refinements is demonstrated with some representative examples from petrology in which different glass substrate thicknesses have been employed. The section of the crystal microvolume must be at least of the same order of magnitude as the focus of the beam (15 × 15 µm in the provided examples). Thanks to its versatility and experimental simplicity, this methodology should be useful for disciplines as disparate as petrology, materials science and cultural heritage.
Reference Key
rius2015iucrjapplication Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Jordi Rius;Oriol Vallcorba;Carlos Frontera;Inmaculada Peral;Anna Crespi;Carles Miravitlles
Journal european journal of orthopaedic surgery & traumatology : orthopedie traumatologie
Year 2015
DOI
10.1107/S2052252515007794
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.