Abstract
OBJECTIVE: To assess the effects of the relief of the mitral stenosis by percutaneous ballon valvotomy in the function of the left atrial appendage. METHODS: Twelve patients with symptomatic mitral stenosis, in sinus rhythm, were studied. They were submitted to the transesophageal echocardiogram before and after effective percutaneous ballon valvotomy. Concerning the left atrial appendage, the peak flow velocities and the respective integral of the anterograde and retrograde flow, in addition to the ejection fraction calculated through the planimetry of the area of that structure, were analyzed at the pulsatile Doppler. RESULTS: There was a significant increase of the anterograde flow velocity of the left atrial appendage after percutaneous ballon valvotomy (pre: mean of 0.30 m/s; post: mean of 0.47 m/s; p<0.05) and their respective integrals. The same happened with the retrograde flow velocity (pre: mean of 0.35 m/s, post: mean of 0.53 m/s; p<0.05). There was a tendency of increase of the ejection fraction of the left atrial appendage after the procedure (pre: mean of 20%, post: mean of 31%; p=0.08). CONCLUSION: The effective opening of the stenosed mitral orifice resulting from the percutaneous ballon valvotomy determined an improvement of the flow pattern of the left atrial appendage, which can potentially contribute for the reduction of the embolic risk.
| Reference Key |
tatani2005arquivosavaliao
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Solange Bernardes Tatani;Orlando Campos Filho;Claudio Henrique Fischer;Valdir Ambrósio Moisés;José Augusto Marcondes de Souza;Cláudia Maria Rodrigues Alves;Angelo Amato Vincenzo de Paola;Antonio Carlos C. Carvalho |
| Journal | revista cubana de ciencias informáticas |
| Year | 2005 |
| DOI |
10.1590/S0066-782X2005000600005
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.