peripapillary retinal nerve fibre layer thickness measurement with sd-oct in normal and glaucomatous eyes:distribution and correlation with age

Clicks: 47
ID: 216765
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #76 of 79 articles by views in The Classical Review

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
AIM:To determine peripapillary retinal fiber layer thickness (RNFL) measured with spectral domain optical coherence tomography (SD-OCT) in normal and glaucomatous eyes in a large sample of exclusively white population and compare results with other similarly constructed studies.METHODS:Average, maximum, minimum and per quadrant RNFL thickness were measured in normal and glaucomatous Greek patients with a scanning laser ophthalmoscope (SLO)/SD-OCT device. The effect of age in normal RNFL thickness was also determined.RESULTS: A total of 278 normal (278 patients) and 67 glaucomatous (67 patients) eyes were included in the study. Average RNFL thickness was 114.8±13.3μm in normal and 92.1±18.5μm in glaucomatous eyes (P<0.001). In normal discs, superior quadrant was the thickest, followed by the inferior, nasal and temporal. Decline of normal RNFL thickness with age was statistically significant for average RNFL thickness (1.92μm per decade of life) and for the superior and inferior quadrants of the disc.CONCLUSION:SD-OCT peripapillary RNFL measurements can be used to distinguish between normal and glaucomatous eyes and establish normative databases, since normal disc measurements differ between different ethnic groups and between different SD-OCT devices.
Reference Key
kampougeris2013internationalperipapillary Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;George Kampougeris;Dimitrios Spyropoulos;Adrianna Mitropoulou;Aggeliki Zografou;Pericles Kosmides
Journal The Classical Review
Year 2013
DOI
10.3980/j.issn.2222-3959.2013.05.21
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.