investigation of fracturing and adhesion behavior of hydroxapatite coating formed by aminoacetic acid-sodium aminoacetate buffer systems

Clicks: 142
ID: 216346
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #119 of 136 articles by views in seminars in cancer biology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 136 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Biomaterials utilized in implantation can be categorized into 4 main categories, as ceramics, polymers, metals and composites. Ceramic-based biomaterials are opted for, particularly in the field of orthopedics. These materials, also named as bioceramics, are usually employed by coating them onto the base material, inasmuch as they are far from the mechanical values of bone. In this study, a hydroxyapatite coating that is fully compatible with human blood plasma was applied on Ti6Al4V alloy through a biomimetic technique using aminoacetic acid-sodium aminoacetate buffer system for the first time in the literature, and examinations related thereto were carried out. The surface of the base material Ti6Al4V alloy was activated with various chemicals. Subsequent to activating the surface, a coating process whereby the base material was kept in simulated body fluid for 24, 48, 72, 96 h was carried out. Ultimate microhardness (indentation) tests were performed to determine the average indentation depths in maximum load, vickers hardness and elasticity modulus of the coatings obtained by using the biomimetic method, while scratch tests were performed to measure the surface bonding strengths of the coating layers. Furthermore, the fracture toughness values of the coating were calculated. The results obtained through the study are evaluated and discussed.
Reference Key
aydn2018metalsinvestigation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;İbrahim Aydın;Mustafa Kırman
Journal seminars in cancer biology
Year 2018
DOI
10.3390/met8030151
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.