ferrule designs and stress distribution in endodontically treated upper central incisors: 3d finite element analysis
Clicks: 718
ID: 216154
2008
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
84.7
/100
718 views
525 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 35 articles by views in international review of management and marketing
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objective: The main goal of this study was to evaluate stress distribution of endodonti-cally treated maxillary central incisors restored with glass fiber posts, composite resin cores, and crowns with different ferrule designs.Materials and Methods: Four three-dimensional models of a maxillary central incisor were modeled in SolidWorks 2006. Tooth with no ferrule, tooth with a 2 mm circumferen-tial ferrule, tooth with a 2 mm beveled ferrule and tooth with a 0.5 mm circumferential ferrule. The teeth were restored with glass fiber posts, composite resin cores, and full ce-ramics crowns. Each model was loaded (1 N) on the palatal side at an angle of 45 degrees to tooth long axis. Von Mises stress findings along the inner surface of the root canals were assessed and compared.Results: The Von Mises Stress at CEJ was the highest in the model without a ferrule when compared to the other models (without ferrule 0.0696, short ferrule 0.0492, cylindrical fer-rule 0.0248, and beveled ferrule 0.0387 MPa).Conclusion: Endodontically treated maxillary central incisors with a ferrule length vary-ing between 0.5 mm and 2.0 mm exhibit lower stress distribution compared to those with-out a ferrule. Keeping a long ferrule is suggested to decrease the stress at the cervical area of restored teeth.
| Reference Key |
ahangari2008journalferrule
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;A. Hassan Ahangari;A. Geramy;A. Valian |
| Journal | international review of management and marketing |
| Year | 2008 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.