diagnosis of vertical root fracture in endodontically treated teeth using computed tomography
Clicks: 322
ID: 214061
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
68.4
/100
322 views
201 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #15 of 51 articles by views in world academy of science, engineering and technology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Vertical root fracture (VRF) is defined as a root fracture in the longitudinal direction, extending from the root to the crown on facial or lingual surfaces. Most VRFs occur in endodontically treated teeth, and the symptoms are similar to those of chronic apical periodontitis or chronic periodontitis. Diagnosing VRF with periapical radiography is difficult. Conversely, cone beam computed tomography (CBCT) provides three-dimensional images and is better at diagnosing VRF than periapical radiography. Therefore, dentists should know how to operate CBCT to obtain clear images and reduce image artifact interferences, thus achieving higher diagnostic accuracy. CBCT imaging includes acquisition configuration, image detection, image reconstruction, and image display. We retrospectively examined four human studies and 19 in vitro studies and focused on certain imaging parameters: field of view selection, voxel size, proper detectors, different image processing methods, and the influence of posts on clear image acquisition. Finally, we discuss the experimental design faults in the reviewed in vitro studies and suggest improvements for future CBCT techniques to achieve higher VRF diagnostic accuracy.
| Reference Key |
huang2015journaldiagnosis
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Chih-Chia Huang;Bor-Shiunn Lee |
| Journal | world academy of science, engineering and technology |
| Year | 2015 |
| DOI |
10.1016/j.jds.2015.01.002
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.