new software to standardize the assessment of embolization of cerebral arteriovenous malformations
Clicks: 134
ID: 211548
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
134 views
23 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #17 of 26 articles by views in iccea 2004 - 2004 3rd international conference on computational electromagnetics and its applications, proceedings
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Staged embolization of high-grade Spetzler-Martin AVMs gains popularity. The assessment of AVM devascularization degree depends on a specialist's personal experience and is very subjective. The goal of our study was to develop software for accurate and objective calculation of AVM devascularization percentage. 34 patients underwent a partial AVM embolization procedure using both adhesive and non-adhesive embolic material. Their pre- and postoperative DICOM angiographic images were assessed by both 4 skilled interventional radiologists and by our new software. We compared the evaluations of AVM devascularization degree made by the software and the specialists. 54 tests were performed. The software was based on a LabVIEW tm platform. The degree of AVM devascularization was estimated in percent values. Mean difference of values was 14,8% 1,6 (range 0%-40%) between human estimations and 3,4% 0,4 (range 0,7-9,2%) between computer calculations. Reliability of the samples was estimated by Kolmogorov-Smirnov criterion. Critical value of the criterion was 2 = 4,89, which corresponds to p value < 0,01. The new software demonstrated adequate efficiency and accuracy to be used for standardization of AVM devascularization degree evaluation.
| Reference Key |
2015patologinew
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Г. С. Сергеев;К. Ю. Орлов;А. Л. Кривошапкин;В. П. Курбатов;М. Е. Амелин;Д. В. Чебыкин;В. А. Панарин;Л. Е. Кальнеус |
| Journal | iccea 2004 - 2004 3rd international conference on computational electromagnetics and its applications, proceedings |
| Year | 2015 |
| DOI |
10.21688/1681-3472-2013-1-25-28
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.