estudo comparativo entre a curva diária de pressão intra-ocular e a associação da curva ambulatorial com o teste de sobrecarga hídrica no glaucoma primário de ângulo aberto, glaucoma de pressão normal e olhos normais comparative study between diurnal intraocular pressure curve and the association of ambulatory intraocular pressure curve with the water-drinking test in open angle glaucoma, normal tension glaucoma and normal eyes
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #20 of 137 articles by views in introducing innodb cluster: learning the mysql high availability stack
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 137 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
PURPOSE: To evaluate and correlate the peaks and the fluctuation of intraocular pressure seen in the association of the ambulatory intraocular pressure curve with the water-drinking test versus the peaks and the fluctuation seen in the daily intraocular pressure curve. METHODS: The sample was as follows: 77 eyes belonging to 77 patients who were divided into three groups composed of 31 eyes belonging to 31 patients with primary open-angle glaucoma, 26 eyes belonging to 26 patients with normal tension glaucoma and 20 normal eyes belonging to 20 individuals. RESULTS: A significant correlation could be observed between the pressure peaks collected from the daily intraocular pressure curve and the pressure peaks seen in the ambulatory intraocular pressure curve, on the water-drinking test, as well as in the association of the ambulatory intraocular pressure curve with the water-drinking test. The procedure which showed the highest rate of correlation between the pressure peaks and the peaks of the daily intraocular pressure curve was the ambulatory intraocular pressure curve (r²= 0.81). However, no statistically significant difference was found between the pressure peaks and the correlation coefficients observed in the other methods. The correlation between the fluctuation of intraocular pressure obtained in the association of the ambulatory intraocular pressure curve with the water-drinking test and the fluctuation of the pressure seen in the daily intraocular pressure curve showed a slight association (r²= 0.21). CONCLUSIONS: The association between ambulatory intraocular pressure curve and water-drinking test was not efficient to estimate peaks and the fluctuation of daily intraocular pressure curve. The ambulatory intraocular pressure curve and the water-drinking test must be analyzed separately. When predicting the peak and the fluctuation of the daily intraocular pressure curve, the ambulatory intraocular pressure curve was the most efficient procedure.
| Reference Key |
meirelles2007arquivosestudo
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Sergio Henrique Sampaio Meirelles;Riuitiro Yamane;Riani Morelo Álvares;Priscilla Barbuto Botelho;Fábio Barreto Morais;Pedro Bertino Moreira;Adalmir Morterá Dantas;Haroldo Vieira de Moraes Júnior |
| Journal | introducing innodb cluster: learning the mysql high availability stack |
| Year | 2007 |
| DOI |
10.1590/S0004-27492007000300015
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.