development of glucose biosensor based on zno nanoparticles film and glucose oxidase-immobilized eggshell membrane
Clicks: 737
ID: 209017
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
91.3
/100
737 views
544 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #1 of 46 articles by views in crystals
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A novel electrochemical glucose biosensor was developed by depositing an ionic liquid (IL) (e.g., 1-ethyl-3-methylimidazolium trifluoromethanesulfonate; [EMIM][Otf]), ZnO nanoparticles (ZnONPs) and eggshell membrane (ESM) on a modified glassy carbon electrode (GCE) for determination of glucose. Glucose oxidase (GOx) was covalently immobilized on eggshell membrane with glutaraldehyde as a cross-linker. Methylene blue was used as a redox indicator to enhance the electron transfer capacity and to ensure stability of both the oxidized and reduced forms in the reaction of enzyme and substrate. The morphological characteristics of microstructures eggshell membranes, chitosan, GOx/ESM, GOx/ZnONPs/IL/ESM and GOx/ZnONPs-IL/CHIT were observed using scanning electron microscopy (SEM). The effects of scan rate, time and pH on the response of glucose biosensors were studied in detail. Under optimal conditions (pH 6.5, 50 s), cyclic voltammetry showed different glucose concentrations on the range of 1 × 10−12 to 0.6 M, with a detection limit of 1 × 10−13 M. The GOx/ZnONPs/IL/ESM was found to be more sensitive as compared to GOx/ZnONPs-IL/CHIT. This developed glucose biosensor detection approach has several advantages such as fast, simple and convenient method, sensitivity, low cost, eco-friendly, low concentrations and remarkable catalytic activities of current signals during glucose reaction.
| Reference Key |
aini2015sensingdevelopment
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Bohari Noor Aini;Shafiquzzaman Siddiquee;Kamaruzaman Ampon;Kenneth Francis Rodrigues;Saallah Suryani |
| Journal | crystals |
| Year | 2015 |
| DOI |
10.1016/j.sbsr.2015.03.004
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.