ultra-trace determination of copper and silver in environmental samples by using ionic liquid-based single drop microextraction-electrothermal atomic absorption spectrometry
Clicks: 297
ID: 207980
2013
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Star Article
76.4
/100
291 views
235 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
A sensitive, selective and effective ionic liquid-based single drop microextraction technique was
developed by using ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate, C6MIMPF6, coupled
with electrothermal atomic absorption spectrometry (ETAAS) for the determination of copper and silver in
environmental samples. Dithizone was used as chelating agent. Several factors that influence the
microextraction efficiency and ETAAS signal, such as pH, dithizone concentration, extraction time, amounts of
ionic liquid, stirring rate, pyrolysis and atomization temperature were investigated and the microextraction
conditions were established. In the optimum experimental conditions, the detection limits (3 s) of the method
were 4 and 8 ng L-1 and corresponding relative standard deviations (0.1 μg L-1, n = 6) were 4.2% and 4.8% for
Ag and Cu, respectively. The developed method was validated by analysis of a certified reference material and
applied to the determination of silver and copper.
developed by using ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate, C6MIMPF6, coupled
with electrothermal atomic absorption spectrometry (ETAAS) for the determination of copper and silver in
environmental samples. Dithizone was used as chelating agent. Several factors that influence the
microextraction efficiency and ETAAS signal, such as pH, dithizone concentration, extraction time, amounts of
ionic liquid, stirring rate, pyrolysis and atomization temperature were investigated and the microextraction
conditions were established. In the optimum experimental conditions, the detection limits (3 s) of the method
were 4 and 8 ng L-1 and corresponding relative standard deviations (0.1 μg L-1, n = 6) were 4.2% and 4.8% for
Ag and Cu, respectively. The developed method was validated by analysis of a certified reference material and
applied to the determination of silver and copper.
| Reference Key |
abolhasani2013journalultra-trace
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|