estudo da força de tração utilizando parafuso excêntrico em placa de compressão dinâmica larga (dcp-l) study of traction force using eccentric screw in large dynamic compression plate (dcp-l)

Clicks: 400
ID: 207601
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #8 of 45 articles by views in current opinion in food science

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJETIVO: Avaliar comparativamente a força de tração (F) determinada com a utilização de parafuso excêntrico em placas do tipo compressão dinâmica larga (DCP-L). MÉTODOS: Foram utilizadas três placas de tipo DCP-L de quatro fabricantes nacionais, todas em aço inoxidável austenítico ASTM F 138, e instrumentais disponíveis nas caixas de 4.5mm. As placas foram fixadas a dois corpos de prova sintéticos de polietileno e a força de tração foi obtida pela utilização de parafuso de 4.5mm, introduzido em furo excêntrico, realizado com instrumentais específicos de cada fabricante. Os resultados foram obtidos por uma máquina servo-hidráulica BME 2000 160/AT, Brasválvula. Os implantes foram divididos em grupos. (Fab. I, II, III, IV). Os testes foram interrompidos após atingir uma força de aperto do parafuso excêntrico de 5 N. RESULTADOS: O grupo I apresentou média de Força máxima (F Max.) 80.58 N; grupo II: F Max. 81.63 N; Grupo III: F Max. 36.32N; Grupo IV: F Max. 37.52N. Utilizando a Análise de Variância de Krukal-Wallis (ANOVA não paramétrica), sendo p= 0,05 existe diferença significativa na força máxima entre os grupos (p = 0,039). CONCLUSÃO: As placas DCP-L do grupo II apresentaram maior força (N) com fixação da placa utilizando parafuso excêntrico. Nível de Evidência: Nível III, estudo analítico.
OBJECTIVE: To comparatively evaluate traction force (F) determined with the use of the eccentric screw in large compression dynamic plates (DCP-L). METHODS: Three DCP-L plates were used, from four national manufacturers, all in austenitic stainless steel ASTM F 138, and instruments available in boxes of 4.5mm. The plates were attached to two specimens of synthetic polyethylene, and traction force was applied using a 4.5mm screw inserted into the eccentric hole, using instruments specific to each manufacturer. The results were obtained by a servo-hydraulic machine BME 2000 160/AT, Brasválvula. The implants were divided into groups. (Fab I, II, III, IV). The tests were stopped after reaching a pinch force of the load screw of 5 N. RESULTS: Group I had a mean peak force (F Max) of 80.58 N; Group II: F Max 81.63 N; Group III: F Max 36.32N; and Group IV: F Max 37.52N. Using Krukal-Wallis Analysis of Variance (ANOVA non-parametric), where p = 0.05, there was a significant difference in maximum strength between the groups (p = 0.039). CONCLUSION: Plates DCP-L of group II showed greater strength (N) with plate fixation using the eccentric screw. Level of Evidence: Level III, analytical study.
ZIEL: Vergleichende Bewertung der Zugkraft (F), die bei der Verwendung einer Exzenterschraube in breiten dynamischen Kompressionsplatten (DCP-L) erzeugt wird. MÉTODEN: Es wurden drei DCP-L-Platten von vier nationalen Herstellern verwendet, alle aus austenitischem Edelstahl nach ASTM F 138, sowie das in den 4,5-mm-Sets verfügbare Instrumentarium. Die Platten wurden an zwei synthetischen Polyethylen-Probekörpern fixiert, und die Zugkraft wurde durch das Einbringen einer 4,5-mm-Schraube in ein mit den spezifischen Instrumenten der jeweiligen Hersteller hergestelltes exzentrisches Loch ermittelt. Die Messwerte wurden mit einer servohydraulischen Prüfmaschine BME 2000 160/AT (Brasválvula) erfasst. Die Implantate wurden in Gruppen eingeteilt (Herst. I, II, III, IV). Die Prüfungen wurden nach Erreichen einer Anzugskraft der Exzenterschraube von 5 N beendet. ERGEBNISSE: Gruppe I wies eine mittlere Maximalkraft (F max.) von 80,58 N auf; Gruppe II: F max. 81,63 N; Gruppe III: F max. 36,32 N; Gruppe IV: F max. 37,52 N. Mittels Kruskal-Wallis-Varianzanalyse (nichtparametrische ANOVA) zeigte sich bei einem Signifikanzniveau von p = 0,05 ein signifikanter Unterschied in der Maximalkraft zwischen den Gruppen (p = 0,039). SCHLUSSFOLGERUNG: Die DCP-L-Platten der Gruppe II wiesen bei der Plattenfixierung mittels Exzenterschraube die höchste Kraft (N) auf. Evidenzniveau: Evidenzgrad III, analytische Studie.
ZIELSETZUNG: Vergleichende Beurteilung der Zugkraft (F), die unter Verwendung der Exzenterschraube bei breiten dynamischen Kompressionsplatten (DCP-L) bestimmt wurde. METHODEN: Es wurden drei DCP-L-Platten von vier nationalen Herstellern verwendet, alle aus austenitischem Edelstahl ASTM F 138, sowie in 4,5-mm-Sets verfügbare Instrumente. Die Platten wurden an zwei synthetischen Polyethylen-Prüfkörpern fixiert, und die Zugkraft wurde unter Verwendung einer 4,5-mm-Schraube aufgebracht, die mit herstellerspezifischen Instrumenten in das exzentrische Loch eingebracht wurde. Die Ergebnisse wurden mit einer servohydraulischen Maschine BME 2000 160/AT, Bras
Reference Key
martins2011actaestudo Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal current opinion in food science
Year 2011
DOI
10.1590/S1413-78522011000300006
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.