non-exhaustive double effort test is reliable and estimates the first ventilatory threshold intensity in running exercise

Clicks: 275
ID: 203033
2018
Free PDF
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #16 of 26 articles by views in kaohsiung journal of medical sciences

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Purpose: The present study aimed to investigate the reliability of the non-exhaustive double effort (NEDE) test in running exercise and its associations with the ventilatory thresholds (VT1 and VT2) and the maximal lactate steady state (MLSS). Methods: Ten healthy male adults (age: 23 ± 4 years, height: 176.6 ± 6.4 cm, body mass: 76.6 ± 10.7 kg) performed 4 procedures: (1) a ramp test for VT1 and VT2 determinations measured by ratio of expired ventilation to O2 uptake (VE/VO2) and expired ventilation to CO2 output (VE/VCO2) equivalents, respectively; (2) the NEDE test measured by blood lactate concentration (NEDELAC) and heart rate responses (NEDEHR); (3) a retest of NEDE for reliability analysis; and (4) continuous efforts to determine the MLSS intensity. The NEDE test consisted of 4 sessions at different running intensities. Each session was characterized by double efforts at the same running velocity (E1 and E2, 180 s), separated by a passive recovery period (90 s rest). LAC and HR values after E1 and E2 (in 4 sessions) were used to estimate the intensity equivalent to “null delta” by linear fit. This parameter represents, theoretically, the intensity equivalent to maximal aerobic capacity. Results: The intraclass correlation coefficient indicated significant reliability for NEDELAC (0.93) and NEDEHR (0.79) (both p < 0.05). There were significant correlations, no differences, and strong agreement with the intensities predicted by NEDELAC (10.1 ± 1.9 km/h) and NEDEHR (9.8 ± 2.0 km/h) to VT1 (10.2 ± 1.1 km/h). In addition, despite significantly lower MLSS intensity (12.2 ± 1.2 km/h), NEDELAC and NEDEHR intensities were highly correlated with this parameter (0.90 and 0.88, respectively). Conclusion: The NEDE test applied to running exercise is reliable and estimates the VT1 intensity. Additionally, NEDE intensities were lower but still correlated with VT2 and MLSS. Keywords: Aerobic exercise, Anaerobic threshold, Maximal lactate steady state, Non-exhaustive protocol, Training prescription, Ventilatory threshold
Reference Key
forte2018journalnon-exhaustive Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal kaohsiung journal of medical sciences
Year 2018
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.