investigation of special asymmetrical modes of three-phase three-leg autotransformers

Clicks: 134
ID: 201707
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #34 of 36 articles by views in indonesian journal of electrical engineering and computer science

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
the base of earlier proposed model calculations were made and were investigated peculiarities of special asymmetric modes of three-phase three legs autotransformer (AT) with tertiary winding, connected in triangle. Calculations were carried out taking into account the electromagnetic coupling of coils, located on different legs. Modules and angles of currents and voltages vectors in autotransformer windings were calculated at breakage of one of the phases of the supply voltage and its simultaneous fault to ground at the side of AT. Based on these data vector diagrams were constructed, which give a visual representation of specific features of such regimes. Considered mode at grounded neutral is characterized by the occurrence of significant currents of the same value in all windings, app. equal to nominal current. Voltage of the windings varies slightly from the nominal values, except for the short-circuited phase. Furthermore, there is a considerable flow of the zero sequence flux, which may lead to additional heating of AT. At ungrounded neutral in this particular mode and absence of load on the secondary AT side, only a small magnetizing currents flows and neutral is significantly displaced. If the load is present, despite of the absence of the current in the neutral, currents in the windings, comparable with the nominal one appeared, also zero sequence flux appeared. In the general case, the currents of this failure (as in the previous case) are much smaller, than the usual short-circuit currents, so are insufficient to trigger the relay protection, this may require additional measures to protect AT against such damage.
Reference Key
v.a2014problemsinvestigation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Bosneaga V.A;Suslov V.M.
Journal indonesian journal of electrical engineering and computer science
Year 2014
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.