gold-coated photonic crystal fiber biosensor based on surface plasmon resonance: design and analysis

Clicks: 260
ID: 201522
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #16 of 46 articles by views in crystals

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The particularly sensitive circular lattice Photonic Crystal Fiber (PCF) based Surface Plasmon Resonance (SPR) sensor is proposed to gain high sensitivity for the detection of unknown analytes. In this model, two-layer PCF based on the SPR has been designed. A plasmonic chemically inactive material gold (Au) with thickness 35 nm is used to the outside of the PCF structure which exhibits negative real permittivity. A circular perfectly match layer (PML) outside the structure is applied to evaluate the performance of the sensor. The raised design has consisted of symmetric air-hole. Three small air-holes are used in second layer and center which help us to produce more evanescent field. Using the wavelength interrogation method the proposed model shows the maximum wavelength sensitivity of 9000 nm/RIU (Refractive Index Unit) and using the amplitude interrogation method it shows the maximum amplitude sensitivity of 318 RIU−1 with maximum sensor resolution 1.11 × 10−5 in the sensing range among analyte 1.34–1.37. Here the proposed model is investigated how phase matching points are varied with changing parameters as like diameter, PML, thickness of gold (Au), sensing layer and pitch. The obtained result reveals that the proposed model may be used in biochemical and biological analyte detection to find out the important application.
Reference Key
chakma2018sensinggold-coated Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Sujan Chakma;Md Abdul Khalek;Bikash Kumar Paul;Kawsar Ahmed;Md Rabiul Hasan;Ali Newaz Bahar
Journal crystals
Year 2018
DOI
10.1016/j.sbsr.2018.02.003
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.