Validation and standardization of the ETP-based activated protein C resistance test for the clinical investigation of steroid contraceptives in women: an unmet clinical and regulatory need.

Clicks: 386
ID: 20099
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #7 of 32 articles by views in Clinical chemistry and laboratory medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background Regulatory bodies recommend the use of an assay based on the assessment of the endogenous thrombin potential (ETP) for the investigation of the activated protein C resistance (APCr) in the development of steroid contraceptives in women. However, the assays described in the literature are home-made and not standardized regarding the method, the reagents, the reference plasma and the quality controls. In the absence of any commercially available method, we aimed at validating the ETP-based APCr assay. Methods The validation was performed according to regulatory standards. The method targets a 90% inhibition of the ETP in healthy donors in the presence of APC compared to the same condition in the absence of APC. As a large-scale production of a pool of plasma from well-selected healthy donors is impossible, algorithms were applied to a commercial reference plasma to correlate with the selected pool. Results Repeatability and intermediate precision passed the acceptance criteria. The assay demonstrated a curvilinear dose response to protein S and APC concentrations (R2 > 0.99). Analysis of plasma samples from 47 healthy individuals (22 women not taking combined hormonal contraceptives [CHC], and 25 men not Factor V Leiden carriers) confirmed the validity of the test, with a mean inhibition percentage of 90%. Investigations in 15 women taking different contraceptives and in two subjects with Factor V Leiden confirmed the good sensitivity and performance of the assay. Conclusions This validation provides the pharmaceutical industry, the regulatory bodies and physicians with a reproducible, sensitive and validated gold-standard ETP-based APCr assay.
Reference Key
douxfils2019validationclinical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Clinical chemistry and laboratory medicine
Year 2019
DOI
10.1515/cclm-2019-0471
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.