estudo morfométrico do coração fetal: sua utilização como parâmetro para análise ecocardiográfica morphometric study of the fetal heart: a parameter for echocardiographic analysis

Clicks: 178
ID: 200888
2008
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #48 of 98 articles by views in india international conference on information processing, iicip 2016 - proceedings

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJETIVO: Avaliar o diâmetro, o perímetro e a área das valvas atrioventriculares do coração fetal, bem como a espessura das paredes ventriculares e os diâmetros das cavidades ventriculares. MATERIAIS E MÉTODOS: Foram dissecados 20 corações de fetos com idade gestacional entre 28 e 36 semanas. Em seguida foram medidos os diâmetros ântero-posterior e transverso e aferidos as áreas e os perímetros das valvas mitral e tricúspide, bem como foram medidas as espessuras das paredes ventriculares e os diâmetros de suas cavidades, utilizando-se um paquímetro com acurácia de1/10 mm. RESULTADOS: Os diâmetros ântero-posterior e transverso da valva atrioventricular esquerda mediram, em média, 10,35 ± 1,62 mm e 9,90 ± 1,79 mm, respectivamente, e os diâmetros ântero-posterior e transverso da valva atrioventricular direita, 10,98 ± 1,90 mm e 9,51 ± 1,81 mm, respectivamente. A área e o perímetro da valva mitral foram de 84,06 ± 25,09 mm² e 29,87 ± 3,96 mm, respectivamente. A área e o perímetro da valva tricúspide mediram, respectivamente, 84,49 ± 26,79 mm² e 28,44 ± 3,85 mm. No ventrículo direito a espessura da parede anterior foi de 5,00 ± 1,70 mm e a da parede posterior foi de 3,83 ± 0,91 mm; no ventrículo esquerdo a espessura da parede anterior foi de 4,25 ± 0,87 mm e a da parede posterior foi de 4,14 ± 0,89 mm. O septo interventricular teve espessura de 4,10 ± 1,13 mm. O ventrículo direito teve como diâmetro ântero-posterior 9,25 ± 0,85 mm, e como diâmetro transverso 8,24 ± 0,42 mm. O ventrículo esquerdo mediu 9,95 ± 0,37 mm para o diâmetro ântero-posterior e 9,20 ± 0,40 mm para o diâmetro transverso. CONCLUSÃO: O conhecimento dos dados morfométricos do coração do feto é de grande importância para o diagnóstico ecocardiográfico de possíveis malformações cardíacas.
OBJECTIVE: To evaluate the diameter, perimeter and area of atrioventricular valves as well thickness of ventricular walls and diameter of ventricular cavity of fetal hearts. MATERIALS AND METHODS: Twenty fetal hearts at gestational age between 28 and 36 weeks were dissected. A paquimeter with 1/10 mm accuracy was utilized for the following morphological measurements: anteroposterior and transverse diameters, mitral and tricuspid valves areas and perimeters. RESULTS: Anteroposterior and transverse diameters of the left atrioventricular valve measured 10.35 ± 1.62 mm and 9.90 ± 1.79 mm, respectively; and anteroposterior and transverse diameters of the right atrioventricular valve measured 10.98 ± 1.90 mm and 9.51 ± 1.81 mm, respectively. Mitral valve area and perimeter were, respectively, 84.06 ± 25.09 mm² and 29.87 ± 3.96 mm. Tricuspid valve area and perimeter were, respectively, 84.49 ± 26.79 mm² and 28.44 ± 3.85 mm. The thicknesses of the anterior and posterior right ventricular walls were, respectively, 5.00 ± 1.70 mm and 3.83 ± 0.91 mm. The thicknesses of the anterior and posterior left ventricular walls were, respectively, 4.25 ±0.87 mm and 4.14 ± 0.89 mm. The thickness of the interventricular septum measured 4.10 ± 1.13 mm. The anteroposterior diameter of the right ventricle was 9.25 ± 0.85 mm, and the transverse diameter was 8.24 ± 0.42 mm. The anteroposterior diameter of the left ventricle measured 9.95 ± 0.37 mm, and transverse diameter measured 9.20 ± 0.40 mm. CONCLUSION: The role of morphometric data of fetal atrioventricular valves is highly significant in the echocardiographic diagnosis of possible congenital cardiac malformations.
Reference Key
cavalcanti2008radiologiaestudo Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Jennecy Sales Cavalcanti;Suzana Marques Duarte
Journal india international conference on information processing, iicip 2016 - proceedings
Year 2008
DOI
10.1590/S0100-39842008000200008
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.