assessment of the use of negative polarity in double-wire mig/mag-welding filling passes
Clicks: 99
ID: 198442
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
29.4
/100
99 views
6 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #49 of 174 articles by views in Journal of applied microbiology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 174 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this work was to evaluate the use of negative polarity in the trail wire in double-wire MIG/MAG-welding filling passes. A comparative study of the conventional technique (two wires working with pulsed DCEP) and the proposed combinations of pulsed DCEP in the lead wire with pulsed DCEN in the trail wire and pulsed DCEP in the lead wire with controlled short-circuit CSC(-) in the trail wire was carried out. The mean current in each wire and the ratio of travel speed to wire feed rate (for the same bead volume per unit weld length), as well as wire type and size, shielding gas composition and joint type (a butt joint in a flat position), were kept constant. Bead surface finish and geometry, deposition efficiency and maximum travel speed for each combination were evaluated. In conclusion, the use of negative polarity in the trail wire increased the deposition rate (higher travel speeds for the same bead) compared with the use of pulsed DCEP in both wires but at the cost of reduced operational robustness, as the conventional technique allowed a sound bead to be produced over a wider range of travel speeds. In addition, beads welded using negative polarity had smaller fusion zones and narrower heat-affected zones but higher convexities.
| Reference Key |
mishchenko2015soldagemassessment
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Andrii Mishchenko;Dumitru Caimacan;Américo Scotti |
| Journal | Journal of applied microbiology |
| Year | 2015 |
| DOI |
10.1590/0104-9224/SI2001.06
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments