development of directly suspended droplet micro extraction method for extraction of organochlorine pesticides in water samples

Clicks: 221
ID: 196470
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #43 of 91 articles by views in ege eğitim dergisi

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A simple and efficient directly suspended droplet micro extraction in conjunction with gas chromatography-electron capture detector (GC-ECD) has been developed for extraction and determination of organochlorine pesticides (OCPs) from water samples. In this technique a micro drop of 1-dodecanol is delivered to the surface of an aqueous sample while being agitated by a stirring bar in the bulk of solution. Factors relevant to the extraction efficiency were studied and optimized. The optimized extraction conditions were extraction solvent: 1-dodecanol; extraction temperature: 60C; NaCl concentration: 0.5M; solvent extraction volume: 10 µL; stirring rate: 800rpm and the extraction time: 20 min. The detection limits of the method were in the range of 0.066–1.85 ngL−1, relation standard deviation (n=5) range were 0.102 - 0.964. A good linearity (r 2 ≥0.995) and a relatively broad dynamic linear range (25–2600ng.L−1) were obtained and recoveries of method were in the range of 90.729% - 102.343%. Finally, the proposedmethod was successfully utilized for pre concentration and determination of OCPs in different real samples.We successfully developed a method based on the DSDME technique combined with capillary GC-ECD for the analysis of OCPs in the water samples and compared with the conventional sample preparation method such as LPME.
Reference Key
rajabi2015journaldevelopment Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Seyed Kamal Rajabi
Journal ege eğitim dergisi
Year 2015
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.