development of directly suspended droplet micro extraction method for extraction of organochlorine pesticides in water samples
Clicks: 221
ID: 196470
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
221 views
21 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #43 of 91 articles by views in ege eğitim dergisi
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple and efficient directly suspended droplet micro extraction in conjunction with gas chromatography-electron capture detector (GC-ECD) has been developed for extraction and determination of organochlorine pesticides (OCPs) from water samples. In this technique a micro drop of 1-dodecanol is delivered to the surface of an aqueous sample while being agitated by a stirring bar in the bulk of solution. Factors relevant to the extraction efficiency were studied and optimized. The optimized extraction conditions were extraction solvent: 1-dodecanol; extraction temperature: 60◦C; NaCl concentration: 0.5M; solvent extraction volume: 10 µL; stirring rate: 800rpm and the extraction time: 20 min. The detection limits of the method were in the range of 0.066–1.85 ngL−1, relation standard deviation (n=5) range were 0.102 - 0.964. A good linearity (r 2 ≥0.995) and a relatively broad dynamic linear range (25–2600ng.L−1) were obtained and recoveries of method were in the range of 90.729% - 102.343%. Finally, the proposedmethod was successfully utilized for pre concentration and determination of OCPs in different real samples.We successfully developed a method based on the DSDME technique combined with capillary GC-ECD for the analysis of OCPs in the water samples and compared with the conventional sample preparation method such as LPME.
| Reference Key |
rajabi2015journaldevelopment
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Seyed Kamal Rajabi |
| Journal | ege eğitim dergisi |
| Year | 2015 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.