Investigating uptake of N2O in agricultural soils using a high-precision dynamic chamber method
Clicks: 270
ID: 19636
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
79.5
/100
270 views
221 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #12 of 28 articles by views in atmospheric measurement techniques
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Uptake (or negative flux) of nitrous oxide (N2O) in agricultural soils
is a controversial issue which has proved difficult to investigate in the
past due to constraints such as instrumental precision and methodological uncertainties. Using a recently developed high-precision
quantum cascade laser gas analyser combined with a closed dynamic
chamber, a well-defined detection limit of 4 μg N2O-N m−2 h−1 could be achieved for individual soil flux measurements. 1220
measurements of N2O flux were made from a variety of UK soils using
this method, of which 115 indicated uptake by the soil (i.e. a negative flux
in the micrometeorological sign convention). Only four of these apparently
negative fluxes were greater than the detection limit of the method, which
suggests that the vast majority of reported negative fluxes from such
measurements are actually due to instrument noise. As such, we suggest that
the bulk of negative N2O fluxes reported for agricultural fields are
most likely due to limits in detection of a particular flux measurement
methodology and not a result of microbiological activity consuming
atmospheric N2O.
| Reference Key |
cowan2014investigatingatmospheric
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Cowan, N. J.;Famulari, D.;Levy, P. E.;Anderson, M.;Reay, D. S.;Skiba, U. M.; |
| Journal | atmospheric measurement techniques |
| Year | 2014 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.