tempo de viabilidade de amostras de sangue venoso bovino destinadas ao exame hemogasomÉtrico, quando mantidas sob conservaÇÃo em Água gelada viability time of blood gas analysis in bovine venous blood samples stored in ice water bath

Clicks: 299
ID: 195060
2001
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #103 of 436 articles by views in Trials

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 436 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Com o objetivo de verificar o tempo de viabilidade de amostras de sangue venoso bovino destinadas ao exame hemogasométrico, quando conservadas em banho de água gelada, selecionaram-se 14 bovinos (7 machos e 7 fêmeas), clinicamente sadios, entre 1 e 5 anos de idade. Colheram-se, de cada animal, 2 amostras de sangue (10ml cada), por punção da veia jugular, com o emprego de seringas plásticas contendo cerca de 1.000UI de heparina sódica, tomando-se os cuidados de eliminar quaisquer bolhas de gás presentes, e de manter vedada a extremidade da agulha com rolha de borracha. Cada uma do par de seringas foi mantida, distintamente, à temperatura ambiente (entre 23 e 30ºC) ou submersa em água gelada (entre zero e 4ºC). As determinações do pH, pressões parciais venosas de dióxido de carbono (PvCO2) e de oxigênio (PvO2), bicarbonato (HCO3-), total de dióxido de carbono (TCO2), excesso ou déficit de bases (BE), bicarbonato padrão (StB), saturação de oxigênio (SatO2) e do conteúdo de oxigênio (O2) foram realizadas imediatamente e com 1, 2, 3, 4, 5, 6, 8, 10, 12 e 24 horas após a colheita. Em cada um dos critérios de manutenção do material, os resultados foram avaliados por meio da análise de variância de medidas repetidas. Consideradas as diferenças entre os valores médios obtidos em cada tempo e aquele da avaliação inicial, os resultados indicaram que as alterações "in vitro" das amostras não conservadas já eram marcantes a partir de 2 ou 3 horas, caracterizando-se por reduções contínuas do pH, PvO2, BE, StB, Sat O2 e O2, e por elevação gradativa da PvCO2. No sangue conservado, ao contrário, o valor de pH não exibiu diferença do original durante as primeiras 4 horas, e os de PvCO2, BE e StB mantiveram-se inalterados por até 6 horas após a colheita. A análise dos resultados permitiu concluir que as amostras de sangue venoso bovino destinadas ao exame de hemogasometria podem permanecer viáveis por até 6 horas, quando adequadamente conservadas em banho de água gelada, mantendo, assim, o seu valor diagnóstico.
In order to verify the viability of blood gas analysis in bovine venous blood stored on ice water bath, two samples (10ml each) were taken from the jugular vein of 14 healthy animals (7 males and 7 females), 1- to 5-year-old, using plastic syringes and attached needles filled with sodium heparin (1,000IU). The blood samples were obtained anaerobically, the air bubbles observed were immediately removed, and the needle was maintened capped with a rubber stopper. Each syringe of the pair was distinctally stored at room temperature (23-30ºC) or in ice water bath (0-4ºC) during the experimental period. Values of pH, carbon dioxide (PvCO2) and oxigen (PvO2) tensions, bicarbonate (HCO3-), total carbon dioxide (TCO2), base excess (BE), standard bicarbonate (StB), oxigen saturation (SatO2), and oxigen content (O2) were determined soon after sampling and after 1, 2, 3, 4, 5, 6, 8, 10, 12 and 24 hours. According to the type of storage temperature, the results were analysed through repeated measurements ANOVA, considering the contrast between the mean value of each time and the initial one. On the storage at room temperature, the in vitro changes were characterized from continuous decreases in pH, PvO2, BE, StB, SatO2, and O2 values, and gradual increase in PvCO2, starting at 2- or 3-hour after the collection. In the samples stored at 0-4ºC, on the other hand, the changes in pH occurred only at the 4th hour, and the stability of the PvCO2, BE, and StB values were maintened for up to the 6th hour. These results indicated that the diagnostic utility of blood gas analysis is conserved in bovine venous blood samples adequately stored up to 6 hours in ice water bath, at 0-4ºC.
Reference Key
lisba2001cinciatempo Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Júlio Augusto Naylor Lisbôa;Fernando José Benesi;Celso Akio Maruta;Regina Mieko Sakata Mirandola;Cynthia Maria Carpigiani Teixeira
Journal Trials
Year 2001
DOI
10.1590/S0103-84782001000200013
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.