comparison of stereotactic core breast biopsy and open surgical biopsy results at a tertiary care hospital in pakistan

Clicks: 7
ID: 194176
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #47 of 48 articles by views in journal of advanced oxidation technologies

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Imrana Masroor, Shaista Afzal, Gulnaz Shafqat, Yasir Jamil KhattakDepartment of Radiology, Aga Khan University Hospital, Karachi, PakistanBackground: The purpose of this study was to determine the yield of stereotactic core breast biopsy and its cost-saving potential.Methods: This observational study was conducted at the Department of Radiology at Aga Khan Hospital in Karachi. All female patients (n = 84) undergoing stereotactic core breast biopsy under mammographic guidance from January 2005 to May 2010 were included. Stereotactic core biopsy was performed on a dedicated mammography unit employing a 14-gauge needle with an automated biopsy device. Ten patients with incomplete medical records were excluded. All breast biopsy results were either compared with surgical findings in cases of malignant histopathological findings or with follow-up needle localization in case of benign core biopsy findings.Results: Fifteen of our 74 patients had malignant findings on stereotactic biopsy, confirmed on histopathology of the final surgical mastectomy specimen. The remaining 59 patients had benign results on histopathology; five patients had needle localization of the same area due to either suspicious mammographic findings or clinical suspicion of malignancy. All were proven to be histopathologically benign on open surgical biopsy. Fifty-four patients with benign results had follow-up mammograms, and the follow-up period was 18 months to 5 years. The sensitivity and specificity was 100%. The cost saving per patient was US$253.Conclusion: Stereotactic core breast biopsy is a safe and cost-effective method for determining the nature of suspicious mammographic findings.Keywords: stereotactic, breast biopsy, BI-RADS®, mammography
Reference Key
i2011internationalcomparison Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Masroor I;Afzal S;Shafqat G;Khattak YJ
Journal journal of advanced oxidation technologies
Year 2011
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.