Traditionally, aeration units, used as a polishing stage after anaerobic digestion (AD) of wastes, are operated at ambient temperature. Yet, when effluent quality is the main design criterion, raising the temperature of the aeration stage can be justified by improved removal efficiencies. In this study, an anaerobic-aerobic sequential system (AASS) was operated to co-digest raw wastewater and food waste. The aerobic compartment was tested under psychrophilic and mesophilic temperatures. At the design loading rate of 2 g L d, the anaerobic digester achieved removal efficiencies of 85 ± 2% of volatile solids (VS), 84 ± 3% of total chemical oxygen demand (COD) and a biogas yield of 1,035 ± 30 mL g (50% methane). The aerobic reactor achieved additional removal of 8% COD and 7 % VS. By raising the temperature of the aerobic reactor to the mesophilic range, COD and solids concentrations of the effluent dropped to approximately half their values. This was accompanied by an increase in nitrification (from 68% to 91%) and denitrification (from 10% to 16%). The energy analysis showed that total energy consumption slightly increases (from 0.45 to 0.49 kWh kg) by raising the temperature of the aerobic reactor to mesophilic range. A preliminary evaluation of the sludge disposal cost, revealed a saving increase of 5-6% under mesophilic operation with respect to psychrophilic conditions. : In order to cope with the globally increasing constraints on the disposal of urban wastes, efficient post-processing of effluents becomes a crucial requirement for the anaerobic digestion industry. In this context, the submitted manuscript shows that the quality of the effluent, of an anaerobic digester, treating food waste with raw wastewater, can be substantially improved by optimizing the aerobic polishing stage. Raising the temperature of the aerobic reactor to the mesophilic range resulted in a drop of solids and COD concentrations to approximately half their values. Equally important, the implications on operational costs were found to be favorable, compared to traditional psychrophilic aerobic post-treatment, when taking into consideration indirect sludge treatment costs and energy selling revenues.
Reference Key
ghanimeh2019anaerobicaerobicjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ghanimeh, Sophia;Abou Khalil, Charbel;Mosca Angelucci, Domenica;Tomei, M Concetta;
Journal Journal of the Air & Waste Management Association (1995)
Year 2019
DOI
10.1080/10962247.2019.1629361
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.