the influence of neonatal intensive care unit design on sound level

Clicks: 266
ID: 191261
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #38 of 111 articles by views in regulatory toxicology and pharmacology : rtp

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Excessive noise in nurseries has been found to cause adverse effects in infants, especially preterm infants in neonatal intensive care units (NICUs). The NICU design may influence the background sound level. We compared the sound level in two differently designed spaces in one NICU. We hypothesized that the sound level in an enclosed space would be quieter than in an open space. Methods: Sound levels were measured continuously 24 hours a day in two separate spaces at the same time, one enclosed and one open. Sound-level meters were placed near beds in each room. Sound levels were expressed as decibels, A-weighted (dBA) and presented as hourly Leq, Lmax, L10, and L90. Results: The hourly Leq in the open space (50.8-57.2 dB) was greater than that of the enclosed space (45.9-51.7 dB), with a difference of 0.4-10.4 dB, and a mean difference of 4.5 dB (p < 0.0001). The hourly L10, L90, and Lmax in the open space also exceeded that in the enclosed space (p < 0.0001). Conclusion: The sound level measured in the enclosed space was quieter than in the open space. The design of bed space should be taken into consideration when building a new NICU. Besides the design of NICU architecture, continuous monitoring of sound level in the NICU is important to maintain a quiet environment.
Reference Key
chen2009pediatricsthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Hsin-Li Chen;Chao-Huei Chen;Chih-Chao Wu;Hsiu-Jung Huang;Teh-Ming Wang;Chia-Chi Hsu
Journal regulatory toxicology and pharmacology : rtp
Year 2009
DOI
10.1016/S1875-9572(09)60076-0
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.