three-dimensional finite element analysis of the stress distribution pattern in the design modifications of u-shaped palatal major connector

Clicks: 368
ID: 191104
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #30 of 150 articles by views in Applied and environmental microbiology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 150 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: The U-shaped maxillary major connector is considered to be the least-desirable design by many prosthodontists as it lacks rigidity, which is a primary requisite for a major connector. Aims and Objectives: Design modifications in the U-shaped palatal major connector are desired because it lacks rigidity. The study also aimed to determine the best design when a U-shaped palatal major connector is indicated for clinical use. Materials and Methods: The normal design and the design-modified models (modification 1, 2, 3, 4) were loaded at the functional cusps of the premolars and the molars with a magnitude of 200 N, 250 N and 300 N at angulations of 60 o and 90 o on both sides of the maxillary arch. Results for each loading were obtained as stress distribution colored images and numerical values were recorded. A three-dimensional finite element analysis study of the design-modified models was performed using two finite element softwares, namely PRO-E and IDEAS. Results: The least stress value of 7.86 Megapascals (MPa) at 200 N, 60 o was recorded for the double-thickness design, followed by design 1, which was 8.03 MPa. The least stress value for the palatal mucosa and ligament was provided by design modification 1 (0.5 mm-thick U-shaped connector, 9 mm anteroposteiorly, 14.6 mm laterally), which was 9.78 MPa and 2.98 MPa, respectively. Conclusion: The double-thickness group exhibited the least internal stress for the U-shaped major connector. However, it delivered the greatest stress to the palatal mucosa and the periodontal ligaments.
Reference Key
hariharan2010indianthree-dimensional Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Ramakrishnan Hariharan;Singh Raj
Journal Applied and environmental microbiology
Year 2010
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.