effect of cast rectifiers on the marginal fit of ucla abutments

Clicks: 122
ID: 190312
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #98 of 106 articles by views in journal of animal and plant sciences

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVES: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. METHODS: Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group - 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (a= 5%). RESULTS: The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68mm to 14.83mm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18mm) similar to those of premachined components (14.3 mm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 mm to 14.6 mm; p<0.05). There were no significant changes after porcelain baking, in both groups. CONCLUSION: The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.
Reference Key
jaime2007journaleffect Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Ana Paula Gumieiro Jaime;Diego Klee de Vasconcellos;Alfredo Mikail Melo Mesquita;Estevão Tomomitsu Kimpara;Marco Antonio Bottino
Journal journal of animal and plant sciences
Year 2007
DOI
10.1590/S1678-77572007000300004
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.